VEGASWING 63
Vibrating level switch for liquids with tube extension

Application area
VEGASWING 63 is used as a universal level switch in all liquids. Independent of the mounting position it detects reliably with millimetre accuracy the level. The instrument can be used in vessels as empty or full detector, as approved overfill protection, dry run protection or pump protection. The position of the switching point is determined through the tube extension. The VEGASWING 63 offers high reliability and security in a wide application range.
Advantages
- Minimum time and cost expenditure thanks to simple setup without medium
- Precise and reliable function through product-independent switching point
- Low maintenance costs
Technical data
Version
with tube extension up to 6 m
Material
316L, ECTFE, PFA
Hastelloy, enamel
Hastelloy, enamel
Process fitting
from G¾A
Process temperature
-50 … +250 °C
Process pressure
-1 … +64 bar
(-100 … +6400 kPa)
(-100 … +6400 kPa)
SIL qualification
up to SIL2
DE
configurator