VEGA

Biogas production

Biogas production<BR>

Biogas reactor

A biogas reactor is a part of the multistage process of digestion. Microorganisms use the complex combination of substances in the digestate as nutrient and energy supply and decompose it. The main product of this decomposition is biogas, which consists of energy-rich methane and carbon dioxide. The generated biogas is collected in a gas tank and converted into electricity and heat in the combined heat and power plant. Defined levels in the individual reactors are required for optimal digestion. Typical process conditions in the reactors are gas overlay, temperatures up to +55 °C and multistage agitators.

Level measurement with VEGAPULS 62

VEGAPULS 62 radar sensors are implemented here for continuous level measurement. These instruments measure the level exactly even under extremely difficult process conditions.

Overfill protection according to WHG with VEGACAP 64

The mandatory overfill protection according to WHG (Water Resource Act) is realized with a VEGACAP 64 capacitive rod measuring probe. It delivers an exact switching point even when covered with the strongly adhesive buildup.

Pressure measurement with VEGABAR 52

To control gas generation, the gas pressure in the reactors is measured with mbar precision. The pressure transmitter VEGABAR 52 has proven itself perfectly suited for this task.

» VEGAPULS 62

Measuring range
up to 35 m
Process fitting
thread from G1½, 1½ NPT
flanges from DN 50, 2"
Process temperature
-200 … +450 °C
Process pressure
-1 … +160 bar
(-100…+16000 kPa)
Measuring precision
+/- 2 mm
SIL qualification
up to SIL2

» VEGACAP 64

Version
fully insulated rod
Measuring range
up to 4 m
Process fitting
thread from G¾, ¾ NPT
flanges from DN 50, 2"
Materials
316L, PTFE
Process temperature
-50 … +200 °C
Process pressure
-1 … +64 bar
(-100 … +6400 kPa)

» VEGABAR 52

Measuring cell
CERTEC
Measuring range
-1 … +72 bar
Permanent product temperature
-40 … +150 °C
Deviation in characteristics
0.2 %, 0.1 %, 0.075%
SIL qualification
up to SIL2