Treatment of special waste
|
|
Special waste - a "cocktail" of chemicals
Lacquers, paints and thinners, among other things, as well as acids, alkalis and emulsions are treated as special waste. Many of these are by-products from applications in the chemical industry, in metal processing and in vehicle construction. In special waste treatment, substances that impact the environment are converted to be compatible with the environment, i.e. capable of being disposed of in waste repositories. Level measurement, e.g. in storage tanks and receiving vessels, ensures automatic, monitored operation of the facility and thereby protects human life and the environment.
|
Level measurement in storage tanks with VEGAPULS 62
Lacquers, paints and thinners are stored in tanks up to 15 m (45.7 ft) high. These substances require no pre-treatment and are fed directly to incinerators via smaller day tanks. Agitators inside the tanks prevent fibrous materials and colour pigments from clumping and settling on the bottom. The VEGAPULS 62 radar sensor is the ideal solution here for level measurement. The radar measurement is unaffected by the ambient conditions, such as strong vapour emission of the waste, and delivers accurate measuring results even when the agitators are in motion.
|
Level detection in the receiving tanks with VEGACAP 64
Capacitive compact level switches, being completely unaffected by buildup, have proven to be a good solution for level detection of lacquers and paints. For that reason, VEGACAP 64 is applied as overfill protection acc. to WHG and as dry run protection for the agitators and discharge pumps.
|
|
|
Level measurement in the receiving vessels with VEGAPULS 63
The receiving vessels are sunk into the ground and are composed of double-walled, plastic-coated steel tanks. Because the delivered acids, alkalis and emulsions have very different properties, the level measurement should be made with non-contacting methods. VEGAPULS 63 radar sensors work reliably under difficult measuring conditions, such as steam, vapours, extreme temperature fluctuation and surface agitation from agitators. Corrosive media, as well as salt deposits caused by neutralisation, are no problem for the buildup-free, flat antenna of top-grade TFM-PTFE plastic.
|
Maximum signal with VEGACAP 63
The maximum signal from the fully PTFE-insulated capacitive level switch VEGACAP 63 stops the filling process and prevents overfill.
|
Leakage detection with VEGASWING 63 and VEGATOR 636 Ex
A leakage warning system is an absolute requirement for double-walled vessels holding water-endangering liquids. The ECTFE-coated vibrating level switch VEGASWING 63 is perfect for this application. In conjunction with the compatible signal conditioning instrument VEGATOR 636 Ex, it fulfils the requirements of SIL 2. The mandatory function test is carried out simply by pressing a key on the signal conditioning instrument.
|
|
|
|
|
VEGAPULS 62
- non-contact measurement of all media - very small minimum distance - reliable function even in strong vapours
|
|
 |
VEGACAP 64
- rugged and maintenance-free - insensitive to buildup, no adjustment required - chemically highly resistant materials
|
|
 |
VEGAPULS 63
- non-contact measurement of all media - very small minimum distance, no mounting boss necessary - chemically highly resistant materials
|
|
|
VEGACAP 63
- rugged and maintenance-free - chemically highly resistant materials
|
|
 |
VEGASWING 63
- product-independent - adjustment-free - AK 3, SIL 2 - high chemical resistance through ETCFE coating
|
|
|
|
|
|
|